MC4 Solar Connect Pair - 1 x Male & 1 x Female MC4 connectors are single-contact electrical connectors commonly used for connecting solar panels. |
MEGA Fuse - 200AMP - 32V (Package of 5 Pieces) Victron MEGA fuses provide circuit protection for high amperage applications. Features:
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. |
MEGA Fuse - 250AMP - 32V (Package of 5 Pieces) Victron MEGA fuses provide circuit protection for high amperage applications. Features:
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. |
MEGA Fuse - 400AMP - 32V (Package of 5 Pieces) Victron MEGA fuses provide circuit protection for high amperage applications. Features:
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. |
MEGA Fuse 300AMP - 32V (Package of 5 Pieces) Victron MEGA fuses provide circuit protection for high amperage applications. Features:
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. |
Mega-Fuse 100A/32V *5-Pack MEGA fuse 100A/32V Specifications:
|
Mega-Fuse 125A/32V *5-Pack MEGA fuse 125A/32V Specifications:
|
Mega-Fuse 150A/32V *5-Pack MEGA fuse 150A/32V Specifications:
|
Mega-Fuse 60A/32V *5-Pack MEGA fuse 60A/32V Specifications:
|
Mega-Fuse 80A/32V *5-Pack MEGA fuse 80A/32V Specifications:
|
Modular Fuse Holder for MEGA Fuse The dovetail feature allows interlocking multiple fuse holders. WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. |
MPPT Control w/ VE Direct port MPPT Control lets you see the status and setup all MPPTs that use a VE.Direct communications port. The new MPPT Control is mounted in the familiar BMV-700 series housing, maintaining a consistent and professional look to your panels and systems monitoring equipment. Features:
|
MultiPlus 12/2000 80-50 120V VE.Bus UL Listed The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features. |
MultiPlus 12/3000 - 120-50 - 230V - VE.Bus The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, and multiple system integration features. Two AC Outputs The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (a second output is available on models rated at 3 kVA and more). Virtually Unlimited Power Thanks to Parallel Operation Up to 6 Multis can operate in parallel to achieve a higher power output. Six 24/5000/120 units, for example, will provide 25 kW / 30 kVA output power with 720 AMP charging capacity. Three Phase Capability In addition to parallel connections, three units of the same model can be configured for three-phase output. But that’s not all up to 6 sets of three units can be connected in parallel for a 75 kW / 90 kVA inverter and more than 2000 Amp charging capacity. PowerControl - Dealing with Limited Generator, Shore Side or Grid Power The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shoreside supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel, a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded. PowerAssist - Boosting the capacity of shore or generator power This feature takes the principle of PowerControl to a further dimension. It allows MultiPlus to supplement the capacity of the alternative source. Where peak power is often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces the spare power is used to recharge the battery. Solar energy: AC Power is Available Even During a Grid Failure The MultiPlus can be used in off-grid as well as grid-connected PV and other alternative energy systems. Loss of mains detection software is available. System Configuring:
On-site Monitoring and Control Several options are available: Battery Monitor, Multi Control Panel, Color control for GX or other GX devices, smartphone, tablet (Bluetooth Smart), laptop, or computer (USB or RS232). Remote Monitoring and Control Color Control GX or other GX devices. Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge. Remote Configuring When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed, and settings can be changed remotely Specifications:
Inverter Specifications:
Charger Specifications:
General Specifications:
Enclosure Specifications:
Standards
|
MultiPlus 12/500 - 20-16 - 120V - VE. Bus UL Approved The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the MultiPlus has several advanced features, as outlined below. Parallel Operation and Three-Phase Capability Up to six Multis can operate in parallel to achieve higher power output. In addition to parallel connection, three units can be configured for three-phase output. PowerControl - Dealing with Limited Generator, Shore Side or Grid Power With the Multi Control Panel, a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded. PowerAssist - Boosting the Capacity of Shore or Generator Power This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load is reduced, the spare power is used to recharge the battery. Four Stage Adaptive Charger and Dual-Bank Battery Charging The main output provides a powerful charge to the battery system using advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Charger datasheet and Victron's website under Technical Information. In addition to this, the MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery. High Start-Up Power It is needed to start high-inrush loads such as power converters for LED lamps, halogen lamps, or electric tools. Search Mode When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode, the Multi, when operating in inverter mode, is switched off in case of no load or very low load and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again. Programmable Relay By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energize in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low). Remote On/Off/Charger On Three pole connector. On-Site System Configuring, Monitoring, and Control After installation, the MultiPlus is ready to go. Some settings can be changed with DIP switches. 500/800/1200VA models: remote switch/battery charge voltage/inverter frequency/search mode. 1600/2000VA models: battery charge voltage/search mode. For more settings use VE-Config or the VE. Bus Smart dongle. Remote Configuring and Monitoring Install a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on Victron's VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed. Specifications:
Inverter Specifications:
Charger Specifications:
General Specifications:
Enclosure Specifications:
Standards:
|
MultiPlus 24/2000 - 50-50 - 120V - VE.Bus UL Approved The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, and multiple system integration features. Two AC Outputs The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (a second output is available on models rated at 3 kVA and more). Virtually Unlimited Power Thanks to Parallel Operation Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity. Three Phase Capability In addition to parallel connections, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units, a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built. Split Phase Options Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split-phase AC source can be obtained by connecting Victron's autotransformer (see data sheet onwww.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz. Power Control - Dealing with Limited Generator, Shore Side or Grid Power The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shoreside supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel, a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded. Powerassist - Boosting the Capacity of Shore or Generator Power This feature takes the principle of PowerControl to a further dimension. It allows MultiPlus to supplement the capacity of the alternative source. Where peak power is often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery. Four-Stage Adaptive Charger and Dual Bank Battery Charging The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on Victron's website under Technical Information. In addition to this, the MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery. System Configuring Has Never Been Easier After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operations can be programmed with DIP switches: no computer is needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced features. Specifications:
Inverter Specifications:
Charger Specifications:
General Specifications:
Enclosure Specifications:
Standards
|
MultiPlus Compact 12/2000/80-150 120V VE.Bus UL Approved The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features. Unique PowerAssist Feature The MultiPlus will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery. Uninterrupted AC Power (UPS Function) In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. Virtually Unlimited Power Thanks To Parallel Operation Up to 6 Multis can operate in parallel to achieve higher power output. Three-phase or split-phase operation is also possible. Please check our datasheets to see which models have paralleling, three-phase, and split-phase capabilities. Remote Monitoring & Control When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more… Please contact your dealer for any returns, repairs or support issues related to this product. |
Multiplus Inverter/Charger 12 VDC - 3000W - 120AMP Battery Charger - 50AMP Transfer Switch (UL LISTED) Features:
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. |
Multiplus Inverter/Charger 24 VDC - 3000W - 70AMP Battery Charger - 50AMP Transfer Switch (UL LISTED) Features:
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. |
Multiplus Inverter/Charger 24 VDC - 3000W - 70AMP Battery Charger - 50AMP Transfer Switch Features:
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. |
MultiPlus-II 12/3000 - 120-50 - 120V The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). PowerAssist The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload occurs. The second level will boost the output of a generator or shoreside supply with power taken from the battery. The MultiPlus-II is the critical component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual. In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more. Please contact your dealer for any returns, repairs, or support issues related to this product. |
MultiPlus-II 12/3000 - 120-50 - 120V The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). PowerAssist The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload occurs. The second level will boost the output of a generator or shoreside supply with power taken from the battery. The MultiPlus-II is the critical component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual. In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more. Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 12/3000 - 120-50 - 120V - UL Approved MultiPlus-II 48/3000 - 35-50 - 120V - UL ApprovedThe MultiPlus-II, an inverter/charger, combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). It also has all the features of the MultiGrid with built-in anti-islanding and increasingly long list of country approvals. PowerAssist The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery. ESS: Energy Storage Systems The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. Uninterrupted AC power (UPS function) In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will operate without disruption. Remote Monitoring and Control When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backup generator and more. Specifications:
Inverter Specifications:
Charger Specifications:
General Specifications:
Enclosure Specifications:
Standards:
*Note: For a short period of time this product was called MultiGrid-II. Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 12/3000 - 120-50 - 2x 120V UL Approved The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). PowerAssist The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload occurs. The second level will boost the output of a generator or shoreside supply with power taken from the battery. The MultiPlus-II is the critical component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual. In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more. Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 24/3000 - 70-50 - 120V The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). PowerAssist The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload occurs. The second level will boost the output of a generator or shoreside supply with power taken from the battery. The MultiPlus-II is the critical component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual. In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more. Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 24/3000 - 70-50 - 120V - UL Approved The MultiPlus-II, an inverter/charger, combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). It also has all the features of the MultiGrid with built-in anti-islanding and increasingly long list of country approvals. PowerAssist The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery. ESS: Energy Storage Systems The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. Uninterrupted AC power (UPS function) In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will operate without disruption. Remote Monitoring and Control When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backup generator and more. Specifications:
Inverter Specifications:
Charger Specifications:
General Specifications:
Enclosure Specifications:
Standards:
*Note: For a short period of time this product was called MultiGrid-II. Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 24/3000 - 70-50 - 2x120V The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals. PowerAssist The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery. ESS: Energy Storage Systems The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. Uninterrupted AC power (UPS function) In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. Remote Monitoring & Control When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backupgenerator and more…" Note: for a short period of time this product was called MultiGrid-II. Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 48/3000 - 35-50 - 120V - UL Approved The MultiPlus-II, an inverter/charger, combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). It also has all the features of the MultiGrid with built-in anti-islanding and increasingly long list of country approvals. PowerAssist The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery. ESS: Energy Storage Systems The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. Uninterrupted AC power (UPS function) In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will operate without disruption. Remote Monitoring and Control When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backup generator and more. Specifications:
Inverter Specifications:
Charger Specifications:
General Specifications:
Enclosure Specifications:
Standards:
*Note: For a short period of time this product was called MultiGrid-II. Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 48/3000 35-50 120V The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external current sensor option which extends the PowerControl and PowerAssist function to 100A. PowerControl and PowerAssist - Boosting the Capacity of the Grid or a Generator A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function). PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.When the load reduces, the spare power is used to recharge the battery. Solar Energy: AC Power Available Even During a Grid Failure The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is compatible with both solar charger controllers and grid-tie inverters. Two AC Outputs The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the battery, like a water heater for example, can be connected to this output. Virtually Unlimited Power Thanks to Parallel, Split Phase and Three Phase Operation Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/3000/35 units, for example, will provide 15 kW / 18 kVA output power with 210 Amps charging capacity. In addition to parallel connection, two units of the same model can be connected for a 240V split phase output, and three units of the same model can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel connected per phase. On-Site System Configuring, Monitoring and Control Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface needed). Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel. Remote Configuring and Monitoring Install a Color Control GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed. Specifications:
Inverter Specifications:
Charger Specifications: AC Input: Input Voltage Range 90-140 VAC / Input Frequency: 45 – 65 Hz Charge Voltage 'Absorption': 57,6 V Charge Voltage 'Float': 55,2 V Storage Mode: 52,8 V Maximum Battery Charge Current: 35 A Battery Temperature Sensor: Yes General Specifications:
Enclosure Specifications:
Standards:
*Note: For a short period of time this product was called MultiGrid-II Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 48/5000 70-95 120V The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external current sensor option that extends the PowerControl and PowerAssist function to 100A. PowerControl and PowerAssist - Boosting the Capacity of the Grid or a Generator A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function). PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a limited period, the MultiPlus-II will compensate for insufficient generator, shore, or grid power with power from the battery. When the load reduces, the spare power is used to recharge the battery. Solar Energy: AC Power Available Even During a Grid Failure The MultiPlus-II can be used in off-grid as well as grid-connected PV and other alternative energy systems. It is compatible with both solar charger controllers and grid-tie inverters. Two AC Outputs The main output has no-break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output. Virtually Unlimited Power Thanks to Parallel, Split Phase, and Three Phase Operation Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/3000/35 units, for example, will provide 15 kW / 18 kVA output power with 210 Amps charging capacity. In addition to parallel connection, two units of the same model can be connected for a 240V split phase output, and three units of the same model can be configured for three-phase output. But that’s not all: up to 6 sets of three units can be parallel connected per phase. On-Site System Configuring, Monitoring, and Control Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface needed). Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, and Digital Multi Control Panel. Remote Configuring and Monitoring Install a Color Control GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed. Specifications:
Inverter Specifications:
Charger Specifications:
General Specifications:
Enclosure Specifications:
Standards:
*Note: For a short period of time this product was called MultiGrid-II Please contact your dealer for any returns, repairs or support issues related to this product. |
MultiPlus-II 12/3000 120-50 2X 120V The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). PowerAssist Specifications:
Inverter Specifications:
Charger Specifications:
General Specifications:
Enclosure Specifications:
Standards:
*Note: For a short period of time this product was called MultiGrid-II. Please contact your dealer for any returns, repairs or support issues related to this product. |
Non-Inverting Remote On-Off Cable Use this cable to connect the following products to the VE.Bus BMS:
The cable translates the remote on/off driver logic from the VE.Bus BMS (normally high, and open circuit in case of alarm) to the logic needed by above products: active pull down to switch off. |
|
|
|
|
Copyright © 2009-2024 A part of the Intelastores, Inc. Store Network Site Designed and Maintained by Inline Internet Systems, Inc. |