- Category 6 Solid-State Building Entrance Protector
- Protects high-performance 4-pair Cat6 outside plant cables as well as Cat6 UTP cables for voice or ISDN low voltage (digital, 75V) applications. Using 110 punchdown in/out. - Recommended Grounding Impedance: <.5 Ohm - Signal Perfect Circuitry - Fused Clamping Level: 75V - Response Time: 1-5 nanoseconds - Capacitance: <5pF - Wires Protected: 4-pairs - Expandable System Protection: SurgeGate Modules can be attached to one another to expand system protection |
- UL listed for Primary (497) and Isolated Loop (497B) applications
- Exceeds TIA/EIA Standards 568 and 758 for CAT 6 performance - Solid-state protection for fastest response - Use between buildings in a campus environment as a building entrance protector or in hostile industrial applications as an isolated loop protector - For use with CISCO POE systems - Can be used in high power POE (POE+) applications - Expandable System Protection - SurgeGate Modules can be attached to one another to expand system protection as your system grows |
Category 6 Solid-State Building Entrance Protector
Protects high-performance 4-pair Cat6 outside plant cables as well as Cat6 UTP cables for voice or ISDN applications (235V). Using 110 punchdown in/out. Recommended Grounding Impedance: <.5 Ohm Signal Perfect Circuitry Fused Clamping Level: 235V Response Time: 1-5 nanoseconds Capacitance: <5pF Suppression Modes: Metallic and Longitudinal Wires Protected: 4-pairs Expandable System Protection: SurgeGate Modules can be attached to one another to expand system protection |
SurgeGate 4 LAN
- ITW Linx SurgeGate 4 LAN - 4 Outlet AC protection - 1 LAN line protected - SurgeGate module mounting capability - 4Transformer spaced AC outlets - 15 Amps - 1 LAN cable protected - SurgeGate Plus auto-resetting technology - Wall or floor mount ITWM4L -Lifetime product warranty with up to $50,000 connected equipment warranty |
Single-height rack mountable 1U chassis
Accommodates up to 6 replaceable RM port modules |
Solid State Category 6 Wall Mount Protection Module
Applications: LAN RJ45 In/Out Agency Approval: UL 497 and 497B Grounding Requirements: Field-installed solid copper wire (6AWG for Primary, 14AWG for Isolated Loop) Recommended Grounding Impedance: <0.5 Ohm Signal Perfect Circuitry Performance Rating: Cat6 Clamping Level: 16V Response Time: 1-5 Nanoseconds Capacitance: <20pF Wires Protected: 8-wires, 4 pairs per port |
Solid State Category 6 Wall Mount Protection Module
Applications: T1, Telco, and analog lines RJ45 In/Out Agency Approval: UL 497 and 497B Grounding Requirements: Field-installed solid copper wire (6AWG for Primary, 14AWG for Isolated Loop) Recommended Grounding Impedance: <0.5 Ohm Signal Perfect Circuitry Performance Rating: Cat6 Clamping Level: 235V Response Time: 1-5 Nanoseconds Capacitance: <20pF Wires Protected: 8-wires, 4 pairs per port |
Solid State Category 6 Wall Mount Protection Module
Applications: PoE RJ45 In/Out Agency Approval: UL 497 and 497B Grounding Requirements: Field-installed solid copper wire (6AWG for Primary, 14AWG for Isolated Loop) Recommended Grounding Impedance: <0.5 Ohm Signal Perfect Circuitry Performance Rating: Cat6 Clamping Level: 75V Response Time: 1-5 Nanoseconds Capacitance: <20pF Wires Protected: 8-wires, 4 pairs per port |
- Category 6 Solid-State Building Entrance Protector
- Protects high-performance 4-pair Cat6 outside plant cables as well as Cat6 UTP cables for LAN/Data applications (16V). Using 110 punchdown in/out. - Recommended Grounding Impedance: <.5 Ohm - Signal Perfect Circuitry - Fused - Clamping Level: 16V - Response Time: 1-5 nanoseconds - Capacitance: <5pF - Wires Protected: 4-pairs - Expandable System Protection: SurgeGate Modules can be attached to one another to expand system protection |
- Analog Station Set and Central Office Line Protector
- Protects up to 2-wires (1-pair) per jack. Using RJ11/45 connectors (pins 4, 5) - Auto-Resetting Technology: PTC resistors open when a surge occurs, protecting your equipment, but unlike other fuses, the PTCs close again once the surge passes. - Expandable modular system - Applications: Analog and Central Office lines for PBX or KSU - Agency Approval: UL 497A (Secondary) - Grounding Requirements: Uses Electrical AC Ground - Recommended Grounding Impedance: <0.5 Ohm - Signal Perfect Circuitry - Auto-Resetting PTCs: 160 mA (8-10 Ohms) - Clamping Level: 260V - Response Time: 1-5 Nanoseconds - Capacitance: <50pF - Suppression Modes: Metallic and Longitudinal - Wires Protected: 2-wires (1-pair) per jack (pins 4, 5) - Termination Type: RJ11/45 |
Single-height rack mountable 1U chassis
Accommodates up to 12 replaceable RM port modules |
- 8 Outlet Rack Mountable AC Surge Protector
- 8-outlet, 15 amp rack-mountable AC surge protector with protect or disconnect circuitry. Fits standard 19 |
Premier Series 4-Outlet AC Surgegate Surge Protector
- 4-outlet AC surge protector, with SurgeGate Plus circuitry and modular mounting capabilities - LED Indicators: 4 - Power Cord: 8 foot, right angle - Number Outlets: 4 - Number Switched Outlets: 4 - Mounting brackets included -Thermal Fusing - Catastrophic Surge Circuit - Over/Undervoltage Protection - Overvoltage Shutoff: 147V ¦8V - Undervoltage Shutoff: 87V ¦8V - Single Pulse Energy Dissipation: 1650 Joules - Peak Impulse Current: 52,000 A - EMI/RFI Noise Filtration: 50db (99.7%) - Line Voltage: 120V (50/60Hz) - Initial Clamping Level: 200V Peak, 141 rms - UL 1449 Suppression Rating: L-N 400V, L-G 400V, N-G 400V - Maximum Current Rating: 15A (1800W) - Response Time: 1-5 Nanoseconds |
- Premier Series 8-Outlet AC Surgegate Surge Protector
- 8-outlet AC surge protector, with SurgeGate Plus circuitry and modular mounting capabilities - LED Indicators: 4 - Power Cord: 8 foot, right angle - Number Outlets: 8 - Number Switched Outlets: 8 - Mounting brackets included -Thermal Fusing - Catastrophic Surge Circuit - Over/Undervoltage Protection - Overvoltage Shutoff: 147V ¦11V - Undervoltage Shutoff: 87V ¦8V - Single Pulse Energy Dissipation: 1650 Joules - Peak Impulse Current: 52,000 A - EMI/RFI Noise Filtration: 50db (99.7%) - Line Voltage: 120V (50/60Hz) - Initial Clamping Level: 200V Peak, 141 rms - UL 1449 Suppression Rating: L-N 400V, L-G 400V, N-G 400V - Maximum Current Rating: 15A (1800W) - Response Time: 1-5 Nanoseconds |
- Analog Station Set and Central Office Line Protector
- Protects up to 4-wires (2-pairs) per jack. Using RJ11/45 connectors (2in/2out, pins 3, 6, 4, 5 protected) - Auto-Resetting Technology: PTC resistors open when a surge occurs, protecting your equipment, but unlike other fuses, the PTCs close again once the surge passes. - Expandable modular system - Applications: Analog and Central Office lines for PBX or KSU Agency Approval: UL 497A (Secondary) - Grounding Requirements: Uses Electrical AC Ground - Recommended Grounding Impedance: <0.5Ohm - Signal Perfect Circuitry - Auto-Resetting PTCs: 160 mA (8-10 Ohms) - Clamping Level: 260V - Response Time: 1-5 Nanoseconds - Capacitance: <50pF - Suppression Modes: Metallic and Longitudinal - Wires Protected: 4-wires (2-pairs) per jack (pins 3, 6, 4, 5) - Termination Type: RJ11/45 |
- Analog Station Set and Central Office Line Protector
- Protects up to 8-wires (4-pairs) using 110 punchdown block on the input and 110 punchdown block or 4 RJ11 or 2 RJ45 on output. - Auto-Resetting Technology: PTC resistors open when a surge occurs, protecting your equipment, but unlike other fuses, the PTCs close again once the surge passes. - Expandable modular system - Applications: Analog and Central Office lines for PBX or KSU - Agency Approval: UL 497A (Secondary) - Grounding Requirements: Uses Electrical AC Ground - Recommended Grounding Impedance: <0.5Ohm - Signal Perfect Circuitry - Auto-Resetting PTCs: 160 mA (8-10 Ohms) - Clamping Level: 260V - Response Time: 1-5 Nanoseconds - Capacitance: <50pF - Suppression Modes: Metallic and Longitudinal - Wires Protected: 50-wires (25-pairs) - Termination Type: 110 punchdown input, RJ11/RJ45 or 110 punchdown output |
- Analog Station Set and Central Office Line Protector
- Protects up to 16-wires (8-pairs) using 110 punchdown in/out. - Auto-Resetting Technology: PTC resistors open when a surge occurs, protecting your equipment, but unlike other fuses, the PTCs close again once the surge passes. - Expandable modular system - Applications: Analog and Central Office lines for PBX or KSU - Agency Approval: UL 497A (Secondary) - Grounding Requirements: Uses Electrical AC Ground - Recommended Grounding Impedance: <0.5 Ohm - Signal Perfect Circuitry - Auto-Resetting PTCs: 160 mA (8-10 Ohms) - Clamping Level: 260V - Response Time: 1-5 Nanoseconds - Capacitance: <50pF - Suppression Modes: Metallic and Longitudinal - Wires Protected: 16-wires (8-pairs) - Termination Type: 110 punchdown |
- Digital Station Set Protector
- Protects up to 25 2-wire or up to 12 4-wire digital station line using RJ21X (Amphenol) connectors (Pins 1-50, Male in/Female out). - Auto-Resetting Technology: PTC resistors open when a surge occurs, protecting your equipment, but unlike other fuses, the PTCs close again once the surge passes. - Expandable modular system - Applications: Digital PBX or KSU - Agency Approval: UL 497A (Secondary) - Grounding Requirements: Uses Electrical AC Ground - Recommended Grounding Impedance: <0.5 Ohm - Signal Perfect Circuitry - Auto-Resetting PTCs: 160 mA (8-10 Ohms) - Clamping Level: 110V - Response Time: 1-5 Nanoseconds - Capacitance: <50pF - Suppression Modes: Metallic and Longitudinal - Wires Protected: 25-pair - Termination Type: RJ21X (Male in/Female out) |
- 66 Block Primary or Secondary 235V Surge Protector
- UL Primary and Secondary listed with 350mA fuse for voice/fax/modem line (235V) - Dual Indicator Lights: Protection OK and Ground Connection OK - Solid-State Protection - Single Pair Protection: Protect only the lines requiring protection - Ideal for Retrofit Applications: Just remove the bridging clips from the block and replace them with the Protector, add the ground connection, and the pair is connected - Grounding Requirements: Field-installed solid copper wire - Recommended Grounding Impedance: <0.5 Ohm - Fuse Rating: 350mA (1.6 Ohms) - Signal Perfect Circuitry - Clamping Level: 235V - Response Time: 1-5 Nanoseconds - Capacitance: <50pF - Suppression Modes: Metallic and Longitudinal - Wires Protected: 2-wires, 1 pair - Termination Type: 66 M Blocks |
- Multiple Ground Bar and Screw Ground Lug for 66 Block Protectors
- Required for use with UltraLinx Protectors (UP3 models) to provide the necessary ground connection from each protected pair to the single point equipment ground. One required per installation of 1-25 preotected pairs. - 66 wiring block not included |
- 66 Block Primary or Secondary 75V Surge Protector
- UL Primary and Secondary listed with 350mA fuse for voice/fax/modem line (75V) - Dual Indicator Lights: Protection OK and Ground Connection OK - Solid-State Protection - Single Pair Protection: Protect only the lines requiring protection - Ideal for Retrofit Applications: Just remove the bridging clips from the block and replace them with the Protector, add the ground connection, and the pair is connected - Grounding Requirements: Field-installed solid copper wire - Recommended Grounding Impedance: <0.5 Ohm - Fuse Rating: 350mA (1.6 Ohms) - Signal Perfect Circuitry - Clamping Level: 75V - Response Time: 1-5 Nanoseconds - Capacitance: <50pF - Suppression Modes: Metallic and Longitudinal - Wires Protected: 2-wires, 1 pair - Termination Type: 66 M Blocks |
|
|
|
|
Copyright © 2009-2024 A part of the Intelastores, Inc. Store Network Site Designed and Maintained by Inline Internet Systems, Inc. |